Charging station interface 4.63-6011

OCPP configuration keys (OCPP 1.5 and 1.6)

Key names for OCPP commands GetConfiguration and ChangeConfiguration. Note that Master-Slave Scope applies for OCPP keys only and not for Web page parameters

Key Name Master-Slave Scope OCPP standard Description Accessibility Type Range, Default or example
DepartureTime Individual No This element is used to indicate when the vehicle intends to finish the charging process. R String
EAmount Individual No Amount of energy reflecting the EV's estimate how much energy is needed to fulfill the user configured charging goal for the current charging session. This might include energy for other purposes than solely charging the HV battery of an EV. R String
OCPPSlaveState Master No OCPP Slave(s) State R String
SSHClientKey Master No This key can be used to authorize the user root of this charge controller to connect to some server via SSH. This authorization can then be used to establish reverse tunnels using the customer specific scripts. R String
INVOKECUSTOMSCRIPT1 Master No This function can be used to invoke a script that was previously stored on the charge controller. E.g. it can be used to trigger ssh to create a reverse tunnel to some known server. This tunnel could then be used for remote login to this charge controller W String
INVOKECUSTOMSCRIPT2 Master No This function can be used to invoke a script that was previously stored on the charge controller. E.g. it can be used to trigger ssh to create a reverse tunnel to some known server. This tunnel could then be used for remote login to this charge controller W String
INVOKECUSTOMSCRIPT3 Master No This function can be used to invoke a script that was previously stored on the charge controller. E.g. it can be used to trigger ssh to create a reverse tunnel to some known server. This tunnel could then be used for remote login to this charge controller W String
RCMB_STATE Individual No RCMB protection state
Maximum values of last transaction
Current values
R String Not active
ChargeBoxSerialNumber Individual No This overrides the serial number of the charge controller manufacturer. Named in OCPP BootNotification ChargeBOXSerialNumber.
NOTE: It can be only set if the value is empty! This precondition is met for re-flashed charge controllers.
R/W String Not Set
ChargePointSerialNumber Master No This is set by charge point manufacturer not the controller manufacturer. The value is sent as ChargePointSerialNumber in OCPP BootNotification. If it's not set or Binary OCPP is configured, the OCPP message value is replaced by the ChargeBoxIdentity value. R/W String Not Set
ErrorsList Individual No List of errors that are currently present in the charge point. R String No Errors
OPKGInstallExtraOption Both No R/W String
CPUFrequency Individual No R String
RCMBTransactionMaxRMS Individual No The max RMS value is saved while a transaction is in progress R String
RCMBTransactionMaxDC Individual No The max DC value is saved while a transaction is in progress R String
InterfacesList Master No List of interfaces and their IPs R String
StopTxnSampledData Both Yes Types of meter values that should be sent as sample data elements in stop transaction messages R/W String Energy.Active.Import.Register
StopTxnAlignedData Both Yes Types of meter values that should be sent as clock aligned data elements in stop transaction messages R/W String Energy.Active.Import.Register
MeterValuesAlignedData Both Yes Comma-separated list of types of meter values that should be sent as clock aligned data elements in separate meter values messages. Supported are 'Energy.Active.Import.Register', 'Power.Active.Import', 'Current.Import' and 'Current.Offered'. R/W String Energy.Active.Import.Register
MeterValuesSampledData Both Yes Comma-separated list of types of meter values that should be sent as sampled data elements in separate meter value messages. Supported are 'Energy.Active.Import.Register', 'Power.Active.Import', 'Current.Import' and 'Current.Offered'. R/W String Energy.Active.Import.Register
MeterPublicKey Individual No Public Key of the cryptography engine of the connected eHZ meter if available R String
MeterSerialNumber Individual No Serial number as reported by the eHZ or ModBus meter R String No Id read yet
SecondMeterSerialNumber Individual No Serial number as reported by the eHZ or ModBus meter R String No Id read yet
OcppMeterCurrent Individual No Phases Current in Ampere measured by ocpp meter R String Not Available
SecondMeterCurrent Individual No Phases Current in Ampere measured by second meter R String Not Available
OcppMeterPower Individual No Computed power consumption in Watt from OCPP meter R String Not Available
SecondMeterPower Individual No Computed power consumption in Watt from second meter R String Not Available
OcppMeterEnergy Individual No Computed energy consumption in Wh. R String Not Available
SecondMeterEnergy Individual No Computed energy consumption in Wh. R String Not Available
OcppMeterIPAddress Individual No Set the IP address of OCPP meter R/W String
SecondMeterIPAddress Individual No Set the IP address of second meter R/W String
APN Master No Access Point Name of the mobile network to be used when establishing connections to the backend system via the built-in modem R/W String UNKNOWN
APNUsername Master No Username to be used for authenticating with the Access Point of the mobile network for connecting with the backend system R/W String
APNPassword Master No Password to be used for authenticating with the Access Point of the mobile network for connecting with the backend system R/W String
IMSI Master No The international mobile subscriber identity (IMSI), a value associated with the SIM card inserted into the built-in modem. If this number is properly read the SIM card is inserted correctly and can be read by the built-in modem. R String
IMEI Master No The international mobile equipment identification (IMEI). A number associated with the hardware of the built-in modem. If this number is present this device has a built-in modem and can properly communicate with the modem. R String
ICCID Master No The integrated circuit card identifier (ICCID) of the SIM card inserted into the built-in modem. R String
Req3GNetworkOperator Master No The name of the network operator to be used in manual mode. If operator name is unknown set the "Scan network operators at boot" parameter to On, then click on "Save & Restart". Then in the state page all the available operator names will be shown. R/W String
Used3GNetworkOperator Master No The name of the network operator the built-in modem is currently connected to. R String UNKNOWN
AvailableNetworks Master No The list of network operators that are available and visible using the current antenna. This value is only properly filled if requested using the "Scan network operators at boot" configuration parameter R String
SIMPIN Master No The PIN number that should be used to unlock the SIM card. This number is only used if the SIM card requires a PIN number. R/W String
LASTWRONGSIMPIN Master No The wrong PIN number that was used last time. R/W String
MODEMNETSTATE Master No Show at which state in the connection sequence the modem is currently operating. Show OK when connected. Additionally APN session duration and traffic are shown. R String
ModemInfo Master No Shows the modem manufacturer, model and firmware revision. R String
ModemAccessTechnology Master No Shows which access technology (2G, 3G, 4G) the modem is currently using. R String Not Available
ModemLastConnError Master No Reason for the last modem APN connection failure R String
LAI Master No Location Area Identity (LAI), composed of Mobile Country Code (MCC), Mobile Network Code (MNC) and Location Area Code (LAC). R String
ChargeBoxIdentity Individual No The id that is sent to the backend and used by the backend to identify the charge point. R/W String +49*839*00000000001
UPnPUUID Individual No The UPnP UUID that this charge controller uses when announcing its presence on the local network. Only used if connected to a local network. R String 12b3074f-5f49-4368-b4d7-fe2ae0663b1c
FirmwareVersion Individual No Firmware version currently running on the charge point. R String 4.63-6011
RCMBVersion Individual No Version of the RCMB module currently connected to the charge point. R String Not available
SupportedFeatureProfiles Master Yes A list of supported Feature Profiles. Possible profile identifiers: Core, FirmwareManagement, LocalAuthListManagement, Reservation, SmartCharging and RemoteTrigger. R String
RfidTagFreeCharging Individual No Rfid Tag for Free Charging with OCPP Full, fixed rfid modes R/W String
HostnameBinaryOCPP Master No The DNS hostname or IP address of the binary ocpp proxy server for the backend system. This parameter is only used if Binary OCPP is selected for the TCP/IP mode R/W String be.elinc.de
OCPP_SERVER_URL Master No The HTTP URL of the OCPP backend system. This URL must be the SOAP endpoint. This parameter is only used if OCPP-S 1.5 or 1.6, the standard OCPP mode is used. If this mode is used a SIM card with a private APN must be used if the charge point should receive remote commands from the backend system as most mobile networks use NAT for normal SIM cards which prevents connections from the backend to the charge point R/W String http://be.elinc.de:8080/OCPPSoapServerIndigoQA/services/CentralSystemService
ChargePointSOAPURL Master No The URL that the charger reports to the backend system. The backend system will use this URL to connect to the charger for any remote requests. R String
OCPPBackendJSONURL Master No The WS/WSS URL of the OCPP backend system. This URL must be the WS/JSON endpoint and begin with either "ws://" or "wss://". This parameter is only used if OCPP-J 1.6 mode is used. The Chargepoint's ID gets automatically appended when connecting to the backend. R/W String ws://be.elinc.de:8080/OCPPJProxyQA/v16/
HTTPBasicAuthPassword Master No The password to be used for HTTP Basic Authorization. If left empty, HTTP Basic Authorization is not used. R/W String
OcppCSR Master No Certificate signing request (for OCPP) in PEM format that corresponds to the private key this charge point generated upon provisioning R String
15118CSR Individual No Certificate signing request (for 15118) in PEM format that corresponds to the private key this charge point generated upon provisioning R String
OcppCertificate Master No Certificate used for SSL connections to the backend W String
15118EvseCertificateAndChain Individual No Certificate used for SSL connections via 15118 W String
OcppUserCaCertificate Master No User CA Certificate (OCPP) R/W String
15118ContractCaCertificate Individual No Contract CA Certificate (Mo Root CA for 15118) R/W String
ChargePointPublicAddress Master No Public address of the ChargePoint. If set, this address is put into the SOAP WSA-from field. If left empty, the public IP gets determined by the application. R/W String
NetworkConfigDHCPHostname Master No Hostname string sent to DHCP server along with a DHCP request. R/W String
StaticNetworkConfigAddress Master No Static LAN IP of the ChargePoint. R/W String 192.168.0.100
StaticNetworkConfigNetmask Master No Netmask to use for the LAN of the ChargePoint. R/W String 255.255.255.0
StaticNetworkConfigGateway Master No Gateway to use for the LAN of the ChargePoint. R/W String 192.168.0.1
StaticNetworkConfigDNS Master No DNS server to use for the LAN of the ChargePoint. R/W String 8.8.8.8
WANRouterPassword Master No Root password for the WAN router access (e.g. for the 'Teltonika RUTXXX'). R/W String admin01
WANRouterDeviceName Master No Name of the device inside the WAN router to obtain the public IP from (e.g. 'wwan0' or '3g-ppp' on the 'Teltonika RUTXXX'). R/W String
SocketType2State Individual No State of TYPE2 socket at connector 1. R String
SocketSchukoState Individual No State of Schuko socket at connector 1. R String
PDL_Power Master No PDL Power R/W String
SignaledCurrentLimit Individual No The current in Ampere that is signaled to the vehicle via PWM. R String
ChargingScheduleAllowedChargingRateUnit Master Yes A list of supported quantities for use in a ChargingSchedule. R String Current
PhasesConnected Individual No This parameter shows, how the number of phases connected to the ChargePoint is configured. R String
WLANSSID Master No WLAN SSID of the WLAN the ChargePoint shall be connected to. R/W String
WLANPassword Master No WLAN password of the WLAN the ChargePoint shall be connected to. The Chargepoint automatically chooses the right encryption of the WLAN. R/W String
WLANNetworkConfigDHCPHostname Master No Hostname string sent to DHCP server along with a DHCP request. R/W String
WLANStaticNetworkConfigAddress Master No Static WLAN IP of the ChargePoint. R/W String 192.168.1.100
WLANStaticNetworkConfigNetmask Master No Netmask to use for the WLAN of the ChargePoint. R/W String 255.255.255.0
WLANStaticNetworkConfigGateway Master No Gateway to use for the WLAN of the ChargePoint. R/W String 192.168.1.1
WLANStaticNetworkConfigDNS Master No DNS server to use for the WLAN of the ChargePoint. R/W String 8.8.8.8
DlmState Individual No DLM State R String
DlmMasterIp Individual No DLM Master IP which is used for DLM-Slaves configured with Master-Fixed-IP. Additionally the connection port can be specified (IP[:port]). R/W String
TempDelta Both No Temperature change in degrees Celsius for which a new temperature measurement report is sent to the backend system. A value of 0 switches the reporting off. R/W Int [0..50] Def:5
RCMBDelta Both No Residual current change for which e new residual current report is sent to the backend system as ocpp status notification, set to 0 to disable, value is indicated in tenth of milliamps R/W Int [0..999] Def:0
MeterValueSampleInterval Both No Interval in seconds after which a new meter value is sent to the backend system during a charging transaction. Set 0 to turn off or to a value greater than or equal to 60 to turn on. R/W Int [0..99999] Def:0
ClockAlignedDataInterval Both No Interval in seconds after which a new meter value is sent to the backend system regardless of whether a charging transaction is ongoing or not. The sending of these values is aligned with the full hour. Set 0 to turn off or to a value greater than or equal to 60 to turn on. R/W Int [0..604800] Def:0
HeartBeatInterval Master Yes The interval in seconds with which OCPP heartbeat messages are sent to the backend system. Modifying this parameter may upset the backend system (OCPP 1.5). R/W Int [10..3600] Def:240
HeartbeatInterval Master Yes The interval in seconds with which OCPP heartbeat messages are sent to the backend system. Modifying this parameter may upset the backend system (OCPP 1.6). R/W Int [10..3600] Def:240
BackendConnectionTimeout Master No The timeout in seconds that is used for establishing an APN connection, establishing a Proxy or Backend connection and for expecting responses from the Backend for OCPP requests. Only reduce this value to a smaller value if you can assure very good network connection. Increase the value to a larger value in case of bad network coverage, if you can accept long user interaction delays. R/W Int [3..300] Def:60
ConnectionTimeOut Both Yes Interval (from successful authorization) until incipient charging session is automatically canceled due to failure of EV user to (correctly) insert the charging cable connector(s) into the appropriate connector(s). R/W Int [10..300] Def:45
NumberOfConnectors Master Yes The number of physical charging connectors of this Charge Point. R Int [0..254] Def:1
GetConfigurationMaxKeys Master Yes Maximum number of requested configuration keys in a GetConfiguration.req PDU. R Int [0..2000] Def:1
TransactionMessageAttempts Individual Yes Determines how often the Charge Point should try to submit a transaction-related message when the Central System fails to process it. R/W Int [1..1000] Def:1000
TransactionMessageRetryInterval Individual Yes Determines how long the Charge Point should wait before resubmitting a transaction-related message that the Central System failed to process. R/W Int [0..1000] Def:0
ResetRetries Individual Yes Number of times to retry an unsuccessful reset of the Charge Point. R/W Int [0..100] Def:100
PortBinaryOCPP Master No The TCP port of the proxy server for binary OCPP communication with the backend system. R/W Int [1..65535] Def:444
OCPPSOAPPortChargePoint Master No The TCP server port on which the charge point accepts incoming connections from the backend system. Many backends require a specific port as only one port is allowed to be used by the backend firewall configuration R/W Int [81..65535] Def:8090
RegenerateOcppCertAndKey Master No Trigger Regeneration of Private Key and Self Signed Certificate for OCPP W Int [0..10000] Def:0
Regenerate15118CertAndKey Both No Trigger Regeneration of Private Key and Self Signed Certificate for 15118 W Int [0..10000] Def:0
TcpWatchdogTimeout Both No This is the time in seconds in which the connection to the backend can be not working until the system reboots. Set it to 0 to disable rebooting R/W Int [0..100000] Def:10800
NetworkConfigDHCPRetries Master No DHCP request number of retries before giving up. R/W Int [0..100000] Def:10
NetworkConfigDHCPTimeout Master No DHCP request timeout in seconds. R/W Int [0..100000] Def:10
NetworkConfigDHCPDelay Master No DHCP request delay between multiple requests in seconds. R/W Int [0..100000] Def:10
WebsocketsPingInterval Master No WebSockets keep-alive interval in seconds or 0 when unused. Using keep-alive on WebSockets layer is especially useful when using a NAT router between ChargePoint and Backend. The ping-pong being sent prevents the NAT router from closing the websockets connection. R/W Int [0..100000] Def:0
OperatorCurrentLimit Individual No The current in amperes that is signaled to the vehicle for charging. This value must be below the maximum current (see state view) of the charger but can be freely configured, even while charging. R/W Int [0..80] Def:16
VentHeatingTempThr Both No Temperature threshold necessary to start or stop the fan or heater R/W Int [-40..100] Def:85
WLANNetworkConfigDHCPRetries Master No DHCP request number of retries before giving up. R/W Int [0..100000] Def:10
WLANNetworkConfigDHCPTimeout Master No DHCP request timeout in seconds. R/W Int [0..100000] Def:10
WLANNetworkConfigDHCPDelay Master No DHCP request delay between multiple requests in seconds. R/W Int [0..100000] Def:10
DlmInput1CurrOffsetPhase1 Master No R/W Int [-1000..0] Def:0
DlmInput1CurrOffsetPhase2 Master No R/W Int [-1000..0] Def:0
DlmInput1CurrOffsetPhase3 Master No Offset added to 'EVSE Sub-Distribution Limit' case external input 1 is high. Note: currently only negative values are supported R/W Int [-1000..0] Def:0
DlmInput2CurrOffsetPhase1 Master No R/W Int [-1000..0] Def:0
DlmInput2CurrOffsetPhase2 Master No R/W Int [-1000..0] Def:0
DlmInput2CurrOffsetPhase3 Master No Offset added to 'EVSE Sub-Distribution Limit' in case external input 2 is high. Note: currently only negative values are supported R/W Int [-1000..0] Def:0
LocalAuthListMaxLength Master Yes Maximum number of identifications that can be stored in the Local Authorization List R Uint [0..1000000] Def:1000000
SendLocalListMaxLength Master Yes Maximum number of identifications that can be send in a single SendLocalList.req R Uint [0..45000] Def:45000
UTCScheduledReboots Both No The UTC hour that is used for house keeping reboots. The charge controller reboots after 30 days to ensure uninterrupted operation. Reboots only occur with no vehicle connected and no customer present. Select a UTC hour in range [0..23] R/W Uint [0..23] Def:1
TempStopThreshold2 Individual No Temperature threshold necessary to stop charging R/W Uint [40..100] Def:85
TempReduceThreshold1 Individual No Temperature threshold necessary to start decreasing the current R/W Uint [40..100] Def:85
ReducedCurrent Individual No Charging current value in Ampere when temperature is above temperature threshold 1 R/W Uint [6..80] Def:16
AmbientCpuDelta Individual No Temperature delta for measurements from CPU temperature sensor. This value should be tuned according to the thermal characteristic of the charge station R/W Uint [0..150] Def:23
PowerLineVoltage Individual No Single phase RMS voltage of the power source feeding the chargepoint in Volts. This is used for current calculation from power values from meter R/W Uint [1..1000] Def:230
OcppMeterTCPPortNumber Individual No Specifies the TCP port of the OCPP modbus meter R/W Uint [0..65535] Def:502
SecondMeterTCPPortNumber Individual No Specifies the TCP port of the OCPP modbus meter R/W Uint [0..65535] Def:502
MCC Master No Mobile country code as determined from the SIM card. This tells you which country your SIM card comes from R Uint [0..2147483647] Def:0
MNC Master No Mobile Network code as determined from the SIM card. This tells you which mobile network operator your SIM card comes from R Uint [0..2147483647] Def:0
LAC Master No Location area code as reported by the built-in modem, this value can be used to determine the location of the charge point R Uint [0..2147483647] Def:0
CellID Master No Cell Id as reported by the built-in modem, this value can be used to determine the finer location of the charge point R Uint [0..2147483647] Def:0
RSSI Master No Receive Signal Strength Indicator as reported by the modem. This parameter is an indication how well the built-in modem can receive signals from the base station. Values meaning: [0: Extremely low], [1: Very low], [2-12: Low], [13-30: Good], [≥ 31: Excellent], [99: Unknown or undetectable] R Uint [0..99] Def:0
ContactorCyclesType2 Individual No The number of times the contactor of the type 2 socket was switching on and off R/W Uint [0..9999999] Def:0
ContactorCyclesSchuko Individual No The number of times the contactor of the schuko socket was switching on and off R/W Uint [0..9999999] Def:0
SchukoFixedCurrent Individual No The current in (A) signaled for schuko connector. R/W Uint [10..99] Def:10
CheckCarOverCurrentStopLimit Individual No When the charging current reported by the OCPP meter exceeds the signaled current by this percentage, charging will be stopped. R/W Uint [10..100] Def:30
RCDAUTORECLOSUREDELAY Both No RCD auto reclosure delay in seconds R/W Uint [5..1800] Def:900
RCDAUTORECLOSUREATTEMPTS Both No RCD auto reclosure attempts R/W Uint [1..10] Def:3
VentHeatingHyst Both No This delta in degree (Celsius) allows to add hysteresis to the fan or heater control. In order to switch off the fan/heater the temperature must be below/above the configured temperature threshold minus/plus this delta. R/W Uint [0..25] Def:4
EnergyManSecondMeterCurrentLim Individual No Current limit for energy management from second meter in Ampere (A) R/W Uint [1..300] Def:80
EnergyManInputPowerCurrentLim Individual No Single Phase RMS current limit for energy management from external input in Ampere (A). Range: From 6A to 80 A. Set to 0A to pause charging R/W Uint [0..80] Def:16
LaMa_ConnectionRate Individual No Secret key for Mennekes EnergyManager Input W Uint [0..100000] Def:16
ConnectorPhaseRotationMaxLength Individual Yes Maximum number of items in a ConnectorPhaseRotation Configuration Key. R Uint [1..255] Def:1
ChargeProfileMaxStackLevel Master Yes Max StackLevel of a ChargingProfile. R Uint [1..255] Def:255
ChargingScheduleMaxPeriods Master Yes Maximum number of periods that may be defined per ChargingSchedule. R Uint [1..255] Def:255
MaxChargingProfilesInstalled Master Yes Maximum number of Charging profiles installed at a time. R Uint [1..255] Def:255
DlmPhase1Limit Master No R/W Uint [0..10000] Def:16
DlmPhase2Limit Master No R/W Uint [0..10000] Def:16
DlmPhase3Limit Master No Overall current limit for DLM available for distribution to EVs R/W Uint [0..10000] Def:16
DlmOperatorPhase1Limit Master No R/W Uint [0..10000] Def:16
DlmOperatorPhase2Limit Master No R/W Uint [0..10000] Def:16
DlmOperatorPhase3Limit Master No Operator current limit for DLM available for distribution to EVs. The 'Operator EVSE Sub-Distribution Limit ' is equal or smaller than the 'EVSE Sub-Distribution Limit'. It can be changed without rebooting the chargepoint. Thus, a backend could use this parameter to alter the energy available for charging EVs dynamically. The backend will not be able to set a value higher than the 'EVSE Sub-Distribution Limit' R/W Uint [0..10000] Def:16
DlmExtMeterMainDistributionLimitPhase1 Master No R/W Uint [0..10000] Def:100
DlmExtMeterMainDistributionLimitPhase2 Master No R/W Uint [0..10000] Def:100
DlmExtMeterMainDistributionLimitPhase3 Master No Current limit for DLM available for distribution to EVs and additional energy loads. This value is typically higher than the 'EVSE Sub-Distribution Limit' above. An external meter is required to detect the energy consumption of the additional load R/W Uint [0..10000] Def:100
DlmExtLoadFallbackPhase1 Master No R/W Uint [0..10000] Def:9999
DlmExtLoadFallbackPhase2 Master No R/W Uint [0..10000] Def:9999
DlmExtLoadFallbackPhase3 Master No In the error case, where the external meter is disconnected or fails, 'External Load Fallback' is assumed as consumption of an additional consumer. Setting to a high value will result in no current available for the EVSE sub-distribution in that particular situation. Thus, charging would stop R/W Uint [0..10000] Def:9999
DlmExtLoadHeadroomPhase1 Master No R/W Uint [0..10000] Def:0
DlmExtLoadHeadroomPhase2 Master No R/W Uint [0..10000] Def:0
DlmExtLoadHeadroomPhase3 Master No Safety margin to avoid transient overload situations. The algorithm will keep headroom towards 'Main Distribution Limit' R/W Uint [0..10000] Def:0
DlmExtLoadAvgLen Master No Meter values will be averaged in order to avoid transients. R/W Uint [2..3600] Def:5
DlmDisconnectedLimit Individual No Current limit when disconnected from DLM network R/W Uint [0..100] Def:6
DlmMinCurrentRating Individual No Minimum current limit that charging should not go below R/W Uint [6..100] Def:6
DlmDiscoveryNetworkId Individual No Several DLM groupings might coexist in one physical LAN. In case of DLM Master-Auto-Discovery, they are distinguished by Master-Auto-Discovery Network Id R/W Uint [0..255] Def:0
DlmCurrImbalanceLim Master No Maximum allowed phase imbalance. DLM will not exceed the 'Current Imbalance Limit' between phases when assigning current to EVs. R/W Uint [0..255] Def:20
DlmPersistentSlavesCount Master No Number of persistent DLM slaves registered in DLM slave database R Uint [0..0] Def:0
DataConsumption Master No Data Consumption (in bytes) for the running month. R Ulong [0..18446744073709551615] Def:0
DataConsumptionLastMonth Master No Data Consumption (in bytes) for the previous month. R Ulong [0..18446744073709551615] Def:0
Config15118 Individual No High Level (15118 protocol) Power Line Communication configuration. R/W Enum (0)Off
(1)On (Offer)
(2)On (Ed2)
Def:Off
Log15118 Individual No Enable the creation of the 15118_log.csv file with the input and output exi stream messages. R/W Enum (0)Off
(1)On
Def:Off
TlsSupport15118 Both No If set to On, TLS communication between EV and EVSE will be used when EV asks for it. If set to Off, it will be up to the EV to decide if to establish a non TLS communication. R/W Enum (0)Off
(1)On
Def:Off
LocalAuthListEnabled Master Yes Whether the Local Authorization List is enabled R Enum (0)Off
(1)On
Def:Off
fll Master No Local fixed authorization list R/W Enum (0)Off
(1)On
Def:Off
DisplayLanguage Individual No The language of display texts on the LCD display, if available. Only has effect if LCD is configured. R/W Enum (0)English
(1)Deutsch/German
(2)Multi-Language EN-DE-FR-NL
Def:Multi-Language EN-DE-FR-NL
RFIDEnable Individual No Enables or disables the RFID reader. Allows preventing error messages if no reader is installed R/W Enum (0)Off
(1)On
Def:On
USBConfigUpdate Both No Allow update of the charge point configuration via USB stick. R/W Enum (0)Off
(1)On
Def:On
USBFirmwareUpdate Both No Allow update of the charge point firmware via USB stick. R/W Enum (0)Off
(1)On
Def:On
USBScriptExecution Both No Allow execution of a script via USB stick. R/W Enum (0)Off
(1)On
Def:Off
CPUPerfMode Individual No CPU performance setting of the ChargePoint. 'Fast' configures maximum performance; 'Normal' configures reduced performance, which is sufficient for most use cases. ATTENTION: please change this setting only, if you know, what your are doing. Changing this setting will result in re-flashing of the bootloader. A reboot is required. Re-flashing will occur during reboot. Do not power off the ChargePoint, while the system is rebooting, as you might brick your system! R/W Enum (0)Fast
(1)Normal
Def:Fast
loglevel Individual No Level for the logging system R/W Enum (0)LOG_LEVEL_NONE
(1)LOG_LEVEL_USER_ERR
(2)LOG_LEVEL_USER_WARN
(3)LOG_LEVEL_USER_INFO
(4)LOG_LEVEL_ERR
(5)LOG_LEVEL_WARN
(6)LOG_LEVEL_INFO
(7)LOG_LEVEL_DBG
(8)LOG_LEVEL_VDBG
(9)LOG_LEVEL_TRACE
Def:LOG_LEVEL_DBG
GaroBoard Both No Enable or disable the use of the Garo Top Board for MCB and RCD inputs R/W Enum (0)Off
(1)On
Def:Off
ConnectionType Master No The type of data connection to be used to connect to the backend system, if any. Use this option to disable backend communication completely R/W Enum (0)No Backend
(1)GSM
(2)Ethernet
(3)USB
(4)WLAN
Def:No Backend
MeterType Individual No The type of meter used for the charging socket and its connector. This is relevant for OCPP transactions. R/W Enum (0)eHZ Meter
(6)Modbus Meter ABB
(19)Modbus B-Control EM300-LR
(20)Modbus Meter Carlo Gavazzi EM200
(21)Modbus Meter Carlo Gavazzi EM340
(7)Modbus Meter Eastron SDM630
(8)Modbus Eastron SDM120_220
(13)Modbus Meter Finder
(12)Modbus Meter Garo EM270
(10)Modbus Meter Garo GNM1D
(9)Modbus Meter Garo GNM3D
(22)Modbus Meter Garo GNM3T
(11)Modbus Meter Garo GM3T
(23)Modbus IME CE4DMID31
(15)Modbus Inepro PRO1_2
(16)Modbus Inepro PRO380
(18)Modbus NZR EcoCount S85
(17)Modbus Optec
(14)Modbus Saia ALE3
(24)Modbus Siemens 7KT1666
(28)Modbus Schneider iEM3555
(25)Modbus B-Control EM300-LR (TCP)
(26)Modbus Siemens 7KM2200 (TCP)
(27)Modbus Phoenix Contact EEM-MB371 (TCP)
(1)S0 Meter Opto C6/5
(2)S0 Meter Opto C8/7
(3)No Meter
Def:eHZ Meter
SecondMeterType Individual No Energy Management: the type of second meter, used only for input to manage the current on the grid. R/W Enum (0)eHZ Meter
(6)Modbus Meter ABB
(19)Modbus B-Control EM300-LR
(20)Modbus Meter Carlo Gavazzi EM200
(21)Modbus Meter Carlo Gavazzi EM340
(7)Modbus Meter Eastron SDM630
(8)Modbus Eastron SDM120_220
(13)Modbus Meter Finder
(12)Modbus Meter Garo EM270
(10)Modbus Meter Garo GNM1D
(9)Modbus Meter Garo GNM3D
(22)Modbus Meter Garo GNM3T
(11)Modbus Meter Garo GM3T
(23)Modbus IME CE4DMID31
(15)Modbus Inepro PRO1_2
(16)Modbus Inepro PRO380
(18)Modbus NZR EcoCount S85
(17)Modbus Optec
(14)Modbus Saia ALE3
(24)Modbus Siemens 7KT1666
(26)Modbus Siemens 7KM2200 (TCP)
(27)Modbus Phoenix Contact EEM-MB371 (TCP)
(25)Modbus B-Control EM300-LR (TCP)
(28)Modbus Schneider iEM3555
(1)S0 Meter Opto C6/5
(2)S0 Meter Opto C8/7
(3)No Meter
Def:No Meter
ModemNetworkOperFmt Master No Indicates if the operator name format is alphanumeric or numeric. Long alphanumeric format can be up to 16 characters long and short format up to 8 characters (refer GSM MoU SE.13) R/W Enum (0)Alphanumeric Long
(1)Alphanumeric Short
(2)Numeric
Def:Alphanumeric Short
ModemNetworkSelMode Master No In Automatic mode the modem chooses the operator. In manual mode the operator specified in requested operator name is used. In Manual/Auto, if manual selection fails, automatic mode is used. R/W Enum (0)Auto
(1)Manual
(2)Manual/Auto
Def:Auto
ModemNetworkType Master No The technology to be used to access the network 2G (GSM), 3G (UTRAN) or 4G (LTE). In auto mode the modem will choose the technology. R/W Enum (0)AUTO
(1)2G
(2)3G
(3)4G
Def:AUTO
ScanNetworkOperators Master No Determines whether upon boot a search for available network operators is carried out. The result can then be requested as separate parameter. The value is automatically set to off after boot. R/W Enum (0)Off
(1)On
Def:Off
ModemNetworkState Master No The current network registration mode of the modem which informs about the technology (2G, 3G, 4G) and about the registration (home network, roaming...) R Enum (0)Disable
(1)Enable
(2)Enable with location
(3)Not Available
Def:Disable
OperatorSelectionMode Master No Operator Selection Mode, Auto or Manual... R Enum (0)Automatic
(1)Manual
(2)Deregister from network
(3)Set Only
(4)Manual/Automatic
(5)Not Available
Def:Automatic
GSMState Master No The registration state to the mobile network. R Enum (0)Not Registered and Not Searching
(1)Registered at Home Network
(2)Not Registered and Searching
(3)Registration Denied
(4)Unknown
(5)Registered (Roaming)
(6)Not Available
Def:Not Available
DataTransferTariffUsage Both No Enables the DataTransfer messages that allow to show Tariff and Total Usage Information. Beware this feature only works with backend systems that support it. If the backend system does not support it, this will prevent all authorizations from being successful R/W Enum (0)Off
(1)On
Def:Off
StopTransactionModeUnplug Both No This allows to modify the behavior of the charger at the end of a transaction. Normal unlocks and stops the transaction already when the vehicle side plug is removed. Stop after unplugging causes a transaction to only be fully stopped when the cable is pulled out from the charging station. Only by RFID/RemoteStop only unlocks after the user interacts with the charger and not already when the vehicle side plug is removed. R/W Enum (0)Normal
(1)Stop only by unplugging
(2)Unlock only by RFID/RemoteStop
(3)Normal + Mode D + RCD detected
Def:Normal
ResetMeterValueS0 Both No Reset meter values after stop transaction to 0. This mode is recommended for S0 or internal meters, as it provides consistent meter values for each transaction. If not enabled the meter values are reset to 0 upon every reboot of the system R/W Enum (0)Off
(1)On
Def:Off
IgnoreParentId Both No This feature allows to ignore the parent id when a different RFID card is used for stopping a transaction than for starting. This is useful for backends that do not use the parent id but that keep track of whether a charger is in charging mode or not R/W Enum (0)Off
(1)On
Def:Off
AuthorizeRemoteTxRequests Both Yes This parameter determines whether after receiving an OCPP RemoteStart request the charger should still send an OCPP Authorize message to the backend system. Some backends require this as OCPP could be interpreted to require this. Some backends are upset if this is done R/W Enum (0)Off
(1)On
Def:On
AllowOfflineTxForUnknownId Both Yes This parameter determines whether a client is allowed to charge in case its authorization cannot be processed because the backend is offline or not reachable. If set to ON, the client is allowed to charge even if it cannot get authenticated from the white list nor from local cache. R/W Enum (0)Off
(1)On
(2)ImmediatelyWhenPlugged
Def:Off
InfoStatusNotifications Both No This parameter determines whether OCPP status notifications that are meant just for informative purposes (such as a temperature report) should be sent to the backend system or not R/W Enum (0)Off
(1)On
Def:On
ErrorStatusNotifications Master No This parameter determines whether OCPP status notifications that are meant to report and error (such as when the plug locking system is broken) should be sent to the backend system or not R/W Enum (0)Off
(1)On
Def:On
UsbErrorStatusNotifications Master No This parameter determines whether USB communication errors between master and slave are reported to backend R/W Enum (0)Off
(1)On
Def:Off
StatusNotificationStrategy Both No This parameter determines on which conditions the ChargePoint changes into the OCCUPIED state. In Occupied on Charging occupied is signaled only when authorization is there and a cable is plugged in. In Occupied on Authorized/Plugged the state changes to occupied already when the charger is authorized with nothing connected or when a cable/vehicle is connected but no authorization has taken place yet R/W Enum (0)Occupied on Authorized/Plugged
(1)Occupied on Charging
Def:Occupied on Charging
DisplayDisconnectAsError Master No Parameter that determines whether an error is signaled to the user when the backend connection is interrupted R/W Enum (0)Off
(1)On
Def:Off
SignedMeterValues Both No Parameter that determines whether signed meter values should be sent as part of OCPP MeterValue and OCPP StopTransaction messages. Some backends have a problem with processing signed meter values. Signed meter values are only available from eHZ meters. R/W Enum (0)Off
(1)On
Def:Off
SignedMeterValuesFormat Both No The format of signed meter values. SML binary blobs are encoded with BASE64. R/W Enum (0)XML
(1)Full SML
(2)Short SML
Def:XML
AuthorizationCacheEnabled Master Yes Parameter that enables the use of the internal cache of RFID UID. If disabled, RFIDs even if reported from the backend with an expiry date are not added to an internal cache. R/W Enum (0)Off
(1)On
Def:On
HTBSendMeterPublicKey Both No Define whether to send the meter's public key to HTB backend. If ON, the meter's public key gets embedded into a proprietary DataTransfer message as defined by HTB which is sent to the backend after each BootNotification. R/W Enum (0)Off
(1)On
Def:Off
idTagLetterCase Both No Parameter that makes the RFID tag management configurable to upper or lower case R/W Enum (0)Lower Case
(1)Upper Case
(2)Lower Case Reversed Byte Order
(3)Upper Case Reversed Byte Order
Def:Lower Case
RestartTransAfterPowerLoss Both No If this parameter is set to enable, the transaction that was interrupted by a power loss is continued once the power is back again R/W Enum (0)Off
(1)On
(2)On (BYES specific)
Def:Off
LocalAuthorizeOffline Both Yes Whether the Charge Point, when offline, will start a transaction for locally authorized identifiers R/W Enum (0)Off
(1)On
Def:On
LocalPreAuthorize Master Yes Whether the Charge Point, when online, will start a transaction for locally authorized identifiers without requesting an Authorize.conf from the Central System R/W Enum (0)Off
(1)On
Def:On
StopTransactionOnEVSideDisconnect Both Yes When set to true, the Charge Point SHALL administratively stop the transaction when the cable is unplugged from the EV. R/W Enum (0)Off
(1)On
Def:On
UnlockConnectorOnEVSideDisconnect Both Yes When set to true, the Charge Point SHALL unlock the cable on Charge Point side when the cable is unplugged at the EV. R/W Enum (0)Off
(1)On
Def:On
ReserveConnectorZeroSupported Master Yes If this configuration key is present and set to true: Charge Point support reservations on connector 0. R Enum (0)Off
(1)On
Def:On
FreeChargingMode Both No This allows to set the OCPP behavior in free charging mode. Note that in case of master slave scenario the slave will be automatically configured to the same mode the master uses R/W Enum (0)No OCPP
(1)With OCPP status notif without auth
(2)With OCPP status notif with auth
(3)With OCPP Full fixed Rfid with auth
(4)With OCPP Full fixed Rfid without auth
(5)With OCPP Full any Rfid
Def:No OCPP
AllowLongOcppGetConfKeys Both No This allows ocpp keys in get configuration command to have more than 500 characters R/W Enum (0)Off
(1)On
Def:Off
StopTransactionOnInvalidId Individual Yes Determines whether the Charge Point will stop an ongoing transaction when it receives a non-Accepted authorization status in a StartTransaction response. R/W Enum (0)Off
(1)On
Def:On
AuthorizeRecentlyConnectedOnly Both Yes Authorization considering the last vehicle or cable change. If it is set to Off, the authorization is done according to the actual cable or vehicle state. If it is set to On, the authorization is done considering the time when the cable or vehicle was plugged. If the cable or vehicle was connected more than 2 minutes before, then the connector with the most recent cable/vehicle state change is authorized. In case of master-slave configuration this parameter has to be set in both master and slave. R/W Enum (0)Off
(1)On
Def:Off
OCPPMode Master No This parameter determines whether backend communication is done using the standard OCPP SOAP/JSON variant or the proprietary Binary OCPP variant of Ebee Smart Technologies. The Binary OCPP variant is working across NAT networks and therefore does not require a private APN for remote messages to arrive at the charge point. Also Binary OCPP uses much less data (factor 20 to 50) than standard OCPP. Binary OCPP however requires a Binary OCPP proxy on the backend side. R/W Enum (0)OCPP-S 1.5
(1)OCPP-S 1.6
(2)OCPP-J 1.6
(3)OCPP-B 1.5
(4)OCPP-B 1.6
Def:OCPP-S 1.5
SSLModeClient Master No Allows to set how strict SSL authentication is, from no authentication (encryption only) to full authentication R/W Enum (0)Normal SSL Auth
(1)Allow expired certificate
(2)Skip host check
(3)Allow expired certificate and skip host check
(4)Encrypt only - No authentication
Def:Encrypt only - No authentication
SSLModeServer Master No Allows to set whether and how to use SSL as a server, from no authentication (encryption only) to full authentication R/W Enum (0)No SSL, Plain HTTP
(1)Normal SSL Auth
(2)Allow expired certificate
(3)Skip host check
(4)Allow expired certificate and skip host check
(5)Encrypt only - No authentication
Def:No SSL, Plain HTTP
ChargePointPublicAddressMode Master No Mode for selecting the public address of the ChargePoint. 'Local device' takes the address from the local communication interface (like e.g. eth0); 'Manual select' takes the address as filled in above; 'Auto select' determines the address by an outside service from the open internet. 'Teltonika RUTXXX' uses this kind of WAN router to obtain the public IP address. R/W Enum (0)Local device
(1)Manual select
(2)Auto select
(3)Teltonika RUTXXX
Def:Local device
NetworkConfigMode Master No Mode for ethernet configuration to be used for the ChargePoint. 'Auto' uses DHCP to configure the ChargePoint's ethernet connection; 'Static' uses the addresses as filled in static network configuration IP; 'DHCP server' assigns a predefined DHCP configuration to other DHCP clients in the same network (range 172.42.23.100-172.42.23.254]; netmask 255.255.255.0; gateway 172.42.23.1; DNS 172.42.23.1). The DHCP server's own IP is 172.42.23.1. Any static network configuration is ignored in case of DHCP server mode. Please consider to switch the 'WAN router' on in case of DHCP server enabled. R/W Enum (0)Auto (DHCP client)
(1)Static
(2)DHCP server
(1)Manual config
(0)Auto (DHCP)
Def:Auto (DHCP client)
WANRouter Both No Enables access from LAN interfaces (Ethernet/WLAN/USB) to WAN (GSM) interface. This will also enable the DNS forwarder. R/W Enum (0)Off
(1)On
Def:Off
FreeCharging Both No This mode allows charging without authorization via RFID or the backend. Charging is started immediately after a vehicle is connected. R/W Enum (0)Off
(1)On
Def:Off
CPDiodeDetection Individual No Set this value to on if you want to check before charging if the diode connected to the control pilot line is connected or not R/W Enum (0)Off
(1)On
Def:Off
WeldCheck Individual No Weld contactor detection (always enabled in CC1612) R/W Enum (0)DISABLE
(1)ENABLE OPTO C6/5
(2)ENABLE OPTO C8/7
Def:DISABLE
LockIfAuthorized Both No If set to On the locking of the actuator is made only after successful authorization. If set to Off, the locking is done when the cable is plugged. R/W Enum (0)Off
(1)On
Def:Off
LockPermanently Individual No If set to On the Type 2 socket locking mechanism stays locked permanently once a charging cable is inserted. R/W Enum (0)Off
(1)On
Def:Off
CheckCarOverCurrent Both No If set to On the current consumed by the vehicle will be checked against the signaled current. If the overload is above 10% the signaled current will be decreased by 10%. If the overload is above the configured percentage limit the charging will be stopped. R/W Enum (0)Off
(1)On
Def:Off
RandomRestartAfterPowerLoss Both No This allow to randomly delay the delivery of energy to the car after a restart after a power loss. In case of many chargepoints connected to the same power line, this feature avoids a high peak of energy consumption in short period of time R/W Enum (0)Off
(1)On
Def:Off
PauseChargingStateD Both No If set to On, charging transactions are paused in case State D is detected. While state D is detected an error is reported to the user. R/W Enum (0)Off
(1)On
Def:Off
AdcCpCalibrationCfg Individual No This parameter allows to enable the ADC calibration for the control pilot line´s states detection. Once calibrated, it is possible to trigger a re-calibration. Note that changes of this parameter require a reboot to take effect. R/W Enum (0)Off
(1)On
(2)Recalibrate
Def:Off
RCDTEST Individual No RCD Test R/W Enum (0)Off
(1)On
Def:Off
RCDRESET Individual No RCD Reset R/W Enum (0)Off
(1)On
Def:Off
RCDAUTORECLOSURE Both No This parameter allows to enable the automatic reclosure of the RCD. In CC612 the auxiliary relay output C3/4 is used R/W Enum (0)Off
(1)On
Def:Off
RCDENABLE Both No This parameter allows to enable RCD detection. It must be Off when there is no RCD connected to the controller. In CC612 the opto input C6/5 is used. R/W Enum (0)Off
(1)On
Def:Off
MCBENABLE Both No This parameter allows to enable MCB detection. It must be Off when there is no MCB connected to the controller. In CC612 the opto input C8/7 is used. R/W Enum (0)Off
(1)On
Def:Off
VentHeatingCtrlMode Both No This parameter allows to enable the activation of an external fan or heater according to the housing temperature or vehicle state R/W Enum (0)Off
(1)Status D (Ventilation Required by vehicle)
(2)Charging (Ventilation)
(3)Above threshold and charging (Ventilation)
(4)Above threshold (Ventilation)
(5)Below threshold (Heating)
Def:Off
TiltDetection Individual No This parameter allows to enable the tilt detection (CC1612 only). R/W Enum (0)Off
Def:Off
WeldCheckAuxRelay Both No When enabled, the auxiliary relay will be activated whenever the contactor is welded. If enabled in CC1612 the RCD test pin is not used but instead the selected ex out output R/W Enum (0)Off
(1)AUX
Def:Off
MonitoringRelayInput Individual No Use a unique input from a monitoring relay to trigger RCD/MCB R/W Enum (0)DISABLE
(1)ENABLE OPTO C8/7
(2)ENABLE OPTO C6/5
Def:DISABLE
EnergyManMeterPowerLimitCfg Individual No Enabling of energy Management from second meter R/W Enum (0)Off
(1)On
Def:Off
EnergyManInputPowerLimitCfg Individual No Enabling of energy Management from external input R/W Enum (0)DISABLE
(1)ENABLE OPTO C6/5
(2)ENABLE OPTO C8/7
Def:DISABLE
ConnectorPhaseRotation Individual No The phase rotation of the ChargePoint in respect to the grid connection. R/W Enum (0)RST (L1/L2/L3, Standard Reference Phasing)
(1)STR (L2/L3/L1, Standard 120 degree rotation)
(2)TRS (L3/L1/L2, Standard 240 degree rotation)
Def:RST (L1/L2/L3, Standard Reference Phasing)
ConnectorPhaseRotationIT Individual No The phase rotation of the ChargePoint in respect to the IT grid connection. R/W Enum (0)L1-L2
(1)L2-L3
(2)L3-L1
Def:L1-L2
ConnectorSwitch3to1PhaseSupported Master Yes If defined and true, this ChargePoint supports switching from 3 to 1 phase during a charging session. R Enum (0)Off
(1)On
Def:Off
GhostCurrentFiltering Individual No Customer specifc wiring of a chargepoint might lead to false meter readings of the internal meter. The internal meter might read current on phases although there is none. Setting 'Ghost current filtering' to on will suppress those false readings. R/W Enum (0)Off
(1)On
Def:Off
WLANNetworkConfigMode Master No Mode for WLAN network configuration to be used for the WLAN of the ChargePoint. 'Auto' uses DHCP to configure the ChargePoint's WLAN network connection; 'Static' uses the address configured in static network configuration IP; R/W Enum (0)Auto (DHCP client)
(1)Static
(1)Manual config
Def:Auto (DHCP client)
DlmMode Individual No Specifies the ChargePoint's role in a DLM network. There MUST be exactly one DLM Master in a DLM network managing multiple DLM-Slaves. Typically, a ChargePoint configured as DLM Master will also host an internal DLM-Slave. Note: A ChargePoint configured as standalone DLM Master will not host an internal DLM-Slave. If used for charging anyway, its power consumption will be not controlled by DLM! R/W Enum (0)Disabled
(1)DLM Master (With internal DLM-Slave)
(2)DLM Master (Standalone)
(3)DLM Slave (Master-Auto-Discovery)
(4)DLM Slave (Master-Fixed-IP)
Def:Disabled
DlmAlgo Master No Dynamic Load Management Algorithm to be used on the DLM Master for load balancing;'Fair Trade (FIFO)' selects a fair distribution algorithm which works in a first-in-first-out manner. In case there is no energy remaining to distribute, the car has to wait for a free slot. R/W Enum (0)Fair Trade (FIFO)
Def:Fair Trade (FIFO)
DlmAllowEVWakeup Master No Signal PWM to those EVs, which deliberately decided not to charge in order to allow them to wakeup and continue charging later. R/W Enum (0)Off
(1)On
Def:On
DlmExtMeterEnabled Master No If enabled, an external, secondary meter allows to also consider the power consumption of additional load. The power available for charging EVs will be adjusted accordingly. Please make sure, 'Meter configuration (Second)' is configured, preferably to a 3-phase, phase aware meter R/W Enum (0)Off
(1)On
Def:Off
DlmExtMeterLocation Master No Specifies, how the external meter is connected: in case the external meter measures the energy of chargepoints and additional consumer altogether, the value shall be set to 'Including EVSE Sub-Distribution', otherwise to 'Excluding EVSE Sub-Distribution' R/W Enum (0)Including EVSE Sub-Distribution
(1)Excluding EVSE Sub-Distribution
Def:Including EVSE Sub-Distribution
DlmRecalcInterval Master No The DLM algorithm will not calculate and re-assign current to it's DLM slaves any faster than at this configured rate. As an exception, EVs getting ready to charge will be considered and assigned current immedeately. R/W Enum (0)1 sec
(1)2 sec
(2)5 sec
(3)15 sec
(4)30 sec
(5)1 min
(6)10 min
(7)15 min
Def:30 sec
DlmInput1CurrOffsetCfg Master No Adds a configurable offset to 'EVSE Sub-Distribution Limit' based on GPI External Input 1 R/W Enum (0)DISABLE
(1)ENABLE OPTO C6/5
(2)ENABLE OPTO C8/7
Def:DISABLE
DlmInput2CurrOffsetCfg Master No Adds a configurable offset to 'EVSE Sub-Distribution Limit' based on GPI External Input 2 R/W Enum (0)DISABLE
(1)ENABLE OPTO C6/5
(2)ENABLE OPTO C8/7
Def:DISABLE
DlmCurrImbalancePreventionEnabled Master No If enabled, DLM will not exceed the 'Current Imbalance Limit' configured R/W Enum (0)Off
(1)On
Def:Off
DlmClearPersistentSlaves Master No Select 'Clear' and 'Save' to clear the database of known DLM slaves R/W Enum (0)-
(1)Clear
Def:-
DlmDisableDiscoveryBroadcast Master No Disables the broadcasting of DLM Discovery beacons in the DLM master. If disabled, DLM slaves will not be able to find their DLM master automatically with the help of the DLM Master-Auto-Discovery feature. R/W Enum (0)Off
(1)On
Def:Off